Low pressure is one of the most common reasons a combi or system boiler stops working. Topping it up takes five minutes and needs no tools on most boilers.
Check the gauge
Look for the pressure gauge on the front or underneath the boiler. With the heating off and the boiler cold, it should read between 1 and 1.5 bar. Many gauges have a green zone. If it’s below 1, or in the red, it needs topping up.
Find the filling loop
The filling loop connects the cold mains to the heating system. It’s usually under the boiler and looks like:
- A silver braided hose with a small valve at each end, or
- A built-in lever or key underneath the boiler on some models (your manual will show where)
Top it up
- Turn the heating off and let the boiler cool.
- Make sure both ends of the hose are connected tightly.
- Open the first valve, then slowly open the second. You’ll hear water flowing.
- Watch the gauge. Close both valves when it reaches about 1.2 bar.
- Reset the boiler if it shows a fault, and turn the heating back on.
If you go over 1.5 bar, bleed a radiator to bring it down a little.
If it keeps dropping
Topping up once after bleeding radiators is normal. Needing to do it every week or two isn’t. Water is escaping somewhere: a small leak on a valve, a faulty pressure relief valve (check for drips from the copper pipe outside), or a failed expansion vessel inside the boiler. That needs an engineer.
This guide is general information. If you’re ever unsure, or anything involves gas, stop and call a Gas Safe registered engineer.