Boiler Fault Code Finder
Pick your boiler brand, type the code on the display, and see what it means and what to do next.
Gas Safe registered, no. 987082
Your boiler’s trying to tell you something. Pick the brand, type the code from the display, and we’ll tell you what it means and whether you can sort it yourself.
Before you do anything
Smell gas? Don’t touch the boiler. Open windows, don’t use switches and call the National Gas Emergency Service on 0800 111 999.
Carbon monoxide alarm sounding? Get everyone outside into fresh air and call 0800 111 999. If anyone feels unwell, get medical help straight away.
Never open the casing. Resetting, topping up the pressure and thawing the condensate pipe are fine. Anything inside the boiler is a job for a Gas Safe registered engineer.
Every code we cover
Worcester Bosch16 codes
| Code | What it means | Can you fix it? |
|---|---|---|
| EA 227 | The boiler tried to light but didn’t detect a flame. | Often, try the steps first |
| CE 207 | Water pressure is too low. | Often, try the steps first |
| EA 229 | The flame went out while the boiler was running. Often a blocked or frozen condensate pipe, or strong wind at the flue. | Often, try the steps first |
| A1 281 | The pump is running with little or no water. Usually low pressure or air in the system. | Often, try the steps first |
| E9 224 | The flue gas overheat thermostat has tripped. | Engineer needed |
| E9 219 | The main heat exchanger has overheated. | Often, try the steps first |
| EA 338 | Too many short burner starts. Often the pump isn’t detecting water. | Often, try the steps first |
| EA 234 | Gas valve fault: the valve coil is disconnected. | Engineer needed |
| C6 214 | Fan fault: the fan isn’t running. | Engineer needed |
| C6 215 | Fan fault: the fan is running too fast. | Engineer needed |
| C6 216 | Fan fault: the fan is running too slowly. | Engineer needed |
| D1 240 | Return temperature sensor fault. | Engineer needed |
| E2 222 | Flow temperature sensor fault. | Engineer needed |
| B7 257 | Internal fault: the control board may need replacing. | Engineer needed |
| H11 | Hot water outlet sensor fault. You still get hot water, with less control over the temperature. | Engineer needed |
| H13 | Service reminder: the yearly service timer has run out. The boiler still works. | Book a service |
Vaillant17 codes
| Code | What it means | Can you fix it? |
|---|---|---|
| F.22 | Water pressure is too low, or there isn’t enough water in the system. | Often, try the steps first |
| F.28 | The boiler failed to light when starting up. | Often, try the steps first |
| F.29 | The flame went out and the boiler couldn’t relight. Often a gas supply interruption or a frozen condensate pipe. | Often, try the steps first |
| F.75 | The boiler didn’t detect a pressure rise when the pump started. Often low pressure or air in the system, sometimes a pump or sensor fault. | Often, try the steps first |
| F.20 | Overheating: the safety cut-out has tripped. | Often, try the steps first |
| F.24 | The temperature is rising too quickly. Usually poor circulation or low pressure. | Often, try the steps first |
| F.23 | The temperature difference across the boiler is too large: water isn’t circulating well. | Often, try the steps first |
| F.27 | The flame sensor is detecting a flame when there shouldn’t be one. | Engineer needed |
| F.61 | Gas valve control fault. | Engineer needed |
| F.62 | The gas valve didn’t shut off quickly enough after the flame went out. | Engineer needed |
| F.63 | Memory (EEPROM) fault on the control board. | Engineer needed |
| F.32 | Fan fault: the fan speed is outside its normal range. | Engineer needed |
| F.00 | Flow temperature sensor faulty or disconnected. | Engineer needed |
| F.01 | Return temperature sensor faulty or disconnected. | Engineer needed |
| F.73 | The water pressure sensor is reading too low, or is disconnected. | Often, try the steps first |
| F.74 | Water pressure too high, or a pressure sensor fault. | Engineer needed |
| Con | The display can’t talk to the boiler’s main control board. | Engineer needed |
Ideal15 codes
| Code | What it means | Can you fix it? |
|---|---|---|
| F1 | Low water pressure. | Often, try the steps first |
| L2 | Ignition lockout: the boiler failed to light. | Often, try the steps first |
| F2 | Flame loss: the flame went out while the boiler was running. | Often, try the steps first |
| FD | No water flow. Often air in the system, low pressure or a pump fault. | Often, try the steps first |
| L1 | Low water flow, or the flow temperature is outside its normal range. | Often, try the steps first |
| LF | Ignition fault: the boiler has locked out for safety. | Often, try the steps first |
| F3 | Fan fault. | Engineer needed |
| F4 | Flow temperature sensor (thermistor) fault, often linked to poor circulation. | Engineer needed |
| F5 | Return temperature sensor (thermistor) fault. | Engineer needed |
| F7 | Mains voltage is too low, so the boiler has switched off for safety. | Often, try the steps first |
| F9 | Circuit board fault. | Engineer needed |
| L5 | The boiler has been reset too many times (five resets within 15 minutes). | Often, try the steps first |
| L6 | Flame detection fault. | Engineer needed |
| L9 | Overheating. Some models show this as H9, HA or LA. | Often, try the steps first |
| C2 | Chip card or internal control fault. | Engineer needed |
Baxi15 codes
| Code | What it means | Can you fix it? |
|---|---|---|
| E119 | Low water pressure. | Often, try the steps first |
| E118 | Water pressure is below 0.5 bar. | Often, try the steps first |
| E133 | The boiler failed to light or lost its flame. Often a gas supply interruption. | Often, try the steps first |
| E110 | Overheating: the safety thermostat has tripped. The pump may be sticking or there’s air in the system. | Often, try the steps first |
| E125 | Water isn’t circulating properly around the boiler. | Often, try the steps first |
| E128 | The flame has failed repeatedly. | Often, try the steps first |
| E160 | Fan or fan wiring fault. | Engineer needed |
| E130 | The flue sensor has tripped. Can be an internal flue fault or a blocked flue outside. | Engineer needed |
| E28 | Flue sensor or air pressure switch fault, or a blocked flue or condensate pipe. | Engineer needed |
| E20 | Central heating temperature sensor fault. | Engineer needed |
| E50 | Hot water temperature sensor fault. | Engineer needed |
| E321 | Hot water temperature sensor fault. | Engineer needed |
| E384 | The boiler is detecting a flame when there shouldn’t be one. | Engineer needed |
| E.02-.07 | Water pressure is low (below 0.5 bar). Shown on Baxi 200 and 400 combis. | Often, try the steps first |
| E.04-.10 | The boiler failed to light, often a gas supply issue. Shown on Baxi 200 and 400 combis. | Often, try the steps first |
Glow-worm13 codes
| Code | What it means | Can you fix it? |
|---|---|---|
| F.22 | Low water pressure in the boiler. | Often, try the steps first |
| F.28 | The boiler failed to light when starting up. | Often, try the steps first |
| F.29 | The flame went out while the boiler was running. | Often, try the steps first |
| F.75 | Pressure sensor fault: the boiler didn’t detect a pressure change when the pump started. Often low pressure or air in the system. | Often, try the steps first |
| F.20 | Overheating: the safety cut-out has tripped. | Often, try the steps first |
| F.24 | The temperature is rising too quickly. | Often, try the steps first |
| F.27 | Fault in flame detection. | Engineer needed |
| F.61 | Gas valve control fault. | Engineer needed |
| F.25 | Flue gas temperature too high. | Engineer needed |
| F.32 | Fan speed outside its normal range. | Engineer needed |
| F.00 | Flow temperature sensor fault. | Engineer needed |
| F.01 | Return temperature sensor fault. | Engineer needed |
| F.73 | Water pressure sensor disconnected or short-circuited. | Engineer needed |
Vokera10 codes
| Code | What it means | Can you fix it? |
|---|---|---|
| A04 | Low water pressure. | Often, try the steps first |
| A01 | Ignition failure: no flame detected. | Often, try the steps first |
| AL40 | Low water pressure (Mynute range). | Often, try the steps first |
| AL41 | Low water pressure (Mynute range). | Often, try the steps first |
| E10 | Flame lockout: an ignition or flame detection problem (Evolve range). | Often, try the steps first |
| A03 | Fan fault. | Engineer needed |
| A02 | Limit thermostat fault, often linked to overheating. | Engineer needed |
| A07 | Overheating in the flow or return water. | Often, try the steps first |
| A06 | Hot water temperature sensor fault. | Engineer needed |
| A09 | Flue temperature sensor fault. | Engineer needed |
Code keeps coming back?
Book a repair online and tell us the code. Our engineer will bring the likely parts.