Pressure too low
If the gauge drops below 1 bar the boiler may stop. Water is leaving the system somewhere. The usual causes:
- A small leak on a radiator valve or under the floor
- Recently bled radiators (this is normal, just top up once)
- A faulty pressure relief valve letting water out through the pipe outside
- A failed expansion vessel inside the boiler
Pressure too high
Above 2.5 to 3 bar when the heating is on is too high. It usually means the filling loop has been left open or is letting by, or the expansion vessel has lost its charge.
How to top up
Find the filling loop under the boiler (a braided hose or a key on some models). With the boiler cold, open the valves slowly until the gauge reads about 1.2 bar, then close them fully. If you have to do this more than once a month, book a repair.
What we do
We pressure-test the system, check the expansion vessel and relief valve, and trace any leak. You get the price for the fix before we start.