Water takes the easiest route. Radiators close to the boiler get the most flow, and those furthest away get least. Balancing evens it out using the lockshield valve on each radiator.
The valves
Each radiator has two valves. One is the control valve (the knob or thermostatic head you turn). The other is the lockshield, usually under a plastic cap, which sets how much water flows through.
How to balance
- Bleed all radiators first and check the boiler pressure.
- Turn the heating off and let it cool. Open every control valve and lockshield fully.
- Turn the heating on and note the order in which radiators get warm.
- On the radiator that heats first, close the lockshield fully, then open it a quarter turn.
- Work through the radiators in the order they warmed, opening each lockshield a little more than the last.
- The radiator that heated last should end up fully open.
Ideally, the pipes into and out of each radiator should differ by about 11 to 12°C on an older system, or around 20°C on a modern condensing system. Measuring that needs a thermometer. Our engineers balance systems as part of repairs and new installs.
This guide is general information. If you’re ever unsure, or anything involves gas, stop and call a Gas Safe registered engineer.