What the noise tells you
| Noise | Usual cause |
|---|---|
| Kettling (rumbling, like a kettle boiling) | Limescale or sludge on the heat exchanger restricting flow |
| Banging when the heating starts | Air in the system, or a pump set too high |
| Gurgling | Air, or a partly frozen condensate pipe in winter |
| Whistling | Low flow through the boiler, often a blockage or a sticking valve |
| Humming | Pump speed or vibration from loose pipe clips |
What we do
We check pressure, pump speed and flow, look at the water quality and the filter, and bleed out air. If sludge or scale is the cause, we’ll explain the options, from a chemical clean to a powerflush, and only recommend what’s needed.
| Gas boiler breakdown call-out, first hourCovers the visit and the first hour on site. Parts and further labour are quoted before we start. | £90 |
|---|---|
| Gas and heating labourAfter the first hour. Charged in 30-minute blocks. | £66 per hour |
| System powerflushTypical 3-bed home with up to 10 radiators. | From £525 |
All prices include VAT at 20%.